An in-ceiling motorized screen should be coordinated before the ceiling is closed. The installer needs the approved model drawing, structural support, opening and clearance dimensions, finished image position, electrical supply, control route and future service access. A ceiling grid or decorative panel is not automatically a structural mounting point.
Do not cut the ceiling from a nominal screen diagonal. The visible image, black borders, drop, bottom bar, housing and mounting points are different dimensions. Use the technical drawing for the exact ordered model and size.
This guide is for:
For overall product selection, review MGF’s electric projection screen range and conference room projection solutions.
Use this table as a site record. Mark one result, write the evidence or deviation in Notes, assign the responsible party and obtain a dated sign-off. The downloadable CSV and PDF versions provide space for a fuller site record.
| Check item | Result | Notes / evidence | Responsible party | Date / sign-off |
|---|---|---|---|---|
| Exact model, size and approved drawing match the packing list | ☐ Pass ☐ Fail ☐ N/A | ________________ | AV contractor | ________________ |
| Independent structural support and load path are complete | ☐ Pass ☐ Fail ☐ N/A | ________________ | General contractor | ________________ |
| Ceiling opening, trim, level and access dimensions match the drawing | ☐ Pass ☐ Fail ☐ N/A | ________________ | Ceiling contractor | ________________ |
| Power, grounding, isolation and circuit protection are complete | ☐ Pass ☐ Fail ☐ N/A | ________________ | Electrician | ________________ |
| Control wiring, receiver location and fallback control are tested | ☐ Pass ☐ Fail ☐ N/A | ________________ | AV integrator | ________________ |
| Sprinklers, lights, HVAC, speakers, cameras and access panels are clear | ☐ Pass ☐ Fail ☐ N/A | ________________ | General contractor | ________________ |
| Lift plan, temporary support, trained personnel and PPE are in place | ☐ Pass ☐ Fail ☐ N/A | ________________ | Installer | ________________ |
| Housing is level, secure and not twisted; moving parts are clear | ☐ Pass ☐ Fail ☐ N/A | ________________ | Installer | ________________ |
| Upper and lower limits, bottom-bar position and full cycles pass | ☐ Pass ☐ Fail ☐ N/A | ________________ | Installer | ________________ |
| Projected grid and real content are centered and aligned | ☐ Pass ☐ Fail ☐ N/A | ________________ | AV integrator | ________________ |
| Final photos, as-built drawing, serial record and owner handover are complete | ☐ Pass ☐ Fail ☐ N/A | ________________ | Project manager / owner representative | ________________ |
| Phase | Required output | Do not proceed until |
|---|---|---|
| Design | Screen type, image size and centerline | Projector, seating and architecture agree |
| Submittal | Approved model drawing and control schedule | Dimensions and interfaces are confirmed |
| Rough-in | Structure, power, control and access | Screen load and service route are coordinated |
| Ceiling closure | Opening, trim and obstructions checked | Housing is level and deployment path is clear |
| Commissioning | Limits, controls and image alignment tested | Full operating cycle passes safely |
| Handover | Drawings, instructions and product records | Owner understands operation and access |
Start with the visible image width and height. Check the farthest viewer, content detail, projector throw and ceiling height. Then choose the aspect ratio—commonly 16:9 or 16:10 for modern presentation systems, with 4:3 retained where a project requires it.
MGF’s current product matrix lists 4:3, 16:9 and 16:10 directions for its concealed in-ceiling electric screen, with 100-inch and 120-inch sizes shown in the supplied catalog range. Treat these as reference configurations; confirm the current model and all dimensions during quotation.
A standard recessed electric screen provides concealed storage and straightforward deployment. A recessed tab-tensioned screen adds side tension where a flatter retractable surface is a higher priority.
MGF’s in-ceiling tab-tension electric screen is a reference direction for premium residential, meeting and integrated AV projects. The selected material, projector geometry and screen size still need project-specific confirmation.
Coordinate the lens position, throw distance, image width and vertical lens shift. Confirm that the screen deploys on the intended image plane without interfering with:
Avoid relying on digital keystone correction to solve a mechanical alignment problem.
Do not treat a generic product page as the installation authority. For the exact model, size, material, voltage and control package, request and archive these documents:
| Document | Minimum content to verify | Source / approval action |
|---|---|---|
| Datasheet | Model code, visible image area, housing dimensions, size range, material, voltage, power and weight. | Request the current file with the quotation; compare it with the purchase order. |
| Technical Drawing | Housing, ceiling opening, trim, mounting points, anchors, black drop, bottom-bar position, clearances and load path. | Request the revision for the exact size; architect and contractors sign the submittal. |
| Wiring Diagram | Supply voltage, grounding, isolation, circuit protection, control terminals, receiver and low-voltage routing. | Electrician and AV integrator approve against local code and the control schedule. |
| Installation Manual | Support method, lift sequence, fasteners, adjustment limits, safety warnings, service access and commissioning steps. | Installer uses the model manual at the workface; do not substitute a similar model. |
| Warranty and Service Terms | Coverage, exclusions, motor/control parts, response route, spare parts and access requirements. | Attach the current order warranty and service contact to the handover package. |
| As-Built and Commissioning Record | Measured opening, support, wiring, limits, cycle results, image alignment, photos and sign-offs. | Owner or facilities team receives the final record before project closeout. |
MGF’s in-ceiling tab-tension electric screen is a reference product direction; confirm whether the selected project uses that or another exact series before requesting documents.
Obtain and approve:
Record the drawing revision. If the model, size, material or control package changes, review the ceiling opening and rough-in again.

Attach the screen to a suitable structural system designed for the product load and local requirements. Do not assume acoustic tile, gypsum board or a suspended ceiling grid can support the screen.
The contractor should confirm:
Build the recess from the current approved drawing, not from a website image. Measure the real opening after framing and before finish work.
Check:
Where possible, dry-fit or mark the housing outline before final ceiling closure.
A concealed product still needs inspection and service. Do not permanently close the motor, control receiver, wiring connections or mounting fasteners behind decorative finishes.
Agree who can remove the trim or access panel and what nearby components must remain movable. Include this information in the as-built drawing.
Complete these controls before lifting or energizing the screen:
Electrical work must follow the supplied diagram and local code. Verify voltage, circuit protection, isolation method, grounding, cable type and connection location for the selected model.
Keep mains and low-voltage control wiring separated as required. Do not energize the product while installation wiring is incomplete or while the deployment path is obstructed.
Decide how the user will operate the screen:
MGF’s supplied product information lists wireless remote and model-dependent voice, app and USB-trigger directions for selected concealed electric products. Confirm the exact included and optional components on the quotation and wiring schedule.
Avoid placing receivers inside metalwork or inaccessible voids without testing signal performance.
Before installation:
Never lift the screen by the fabric or bottom bar.
Install the housing to the approved mounting points. Check level along the full product length and verify that the housing is not twisted. Uneven mounting can affect deployment, bottom-bar alignment and surface tracking.
Tighten fasteners to the specified method, maintain trim alignment and confirm the opening does not press against moving parts.
With the area clear, connect power and controls according to the product documentation. Perform a controlled short movement first. Listen for abnormal noise and verify that the bottom bar travels freely.
Do not repeatedly change motor limits without authorization. Incorrect adjustment can pull the surface too far into the housing or allow excessive deployment.
Use this project baseline unless the exact model manual, approved submittal or local code requires a stricter condition. Record the measured result rather than writing only “works.”
| Test | Test condition | Pass / Fail standard | Evidence and final approver |
|---|---|---|---|
| Run count | Perform 3 complete down-and-up cycles with the deployment path clear. | No binding, contact, unexpected stopping or change in tracking across all cycles. | Record cycle count; Installer and AV lead |
| Abnormal noise and contact | Listen during start, travel and stop with the room quiet. | No scraping, rubbing, rattling, repeated clicking, impact or abnormal vibration; compare with the approved sample or manual. | Record location and audio/photo evidence; Installer |
| Bottom-bar level | Measure left-to-right difference when fully deployed and record the value in mm. | Within the exact drawing/manual tolerance; if no numeric tolerance is supplied, obtain written project acceptance before handover. | Record measured mm; Installer and owner representative |
| Upper and lower limits | Run to both programmed stops with trim, housing and furniture clear. | No overtravel, housing impact, incomplete drop or unsafe bottom-bar position; record stop positions. | Record limit settings; Installer |
| Control response | Test the primary control three times, then test the fallback method. | Movement begins within 2 seconds as a project baseline, or within the agreed control specification, with no missed or contradictory commands. | Record measured response and control type; AV integrator |
| Image alignment | Project a grid and real content after the screen is fully settled. | Image centerline and visible area match the approved drawing; record any offset in mm and do not solve structural misalignment with excessive keystone. | Photo of grid and sign-off; AV lead and owner |
| Final acceptance | Review the checklist, documents, photos, as-built drawing and owner instructions. | All open deviations have an owner and due date; final acceptance is dated and signed. | AV lead, installer and owner/facilities representative |
Run at least one complete down-and-up cycle while checking:
Project a grid and real content. Confirm the image fits the visible area without using excessive keystone correction.
Give the owner or facilities team:
Take photographs of the concealed structure, wiring route and product label before the ceiling is fully closed.
It may be possible if suitable structure, power, opening dimensions and access can be created, but recessed products are much easier and safer to coordinate before ceiling closure.
Use the approved technical drawing for the exact ordered model. The opening cannot be calculated reliably from the screen diagonal alone.
Follow the product electrical documentation and local code. Circuit and isolation requirements vary by project and destination market.
Yes. The motor, controls, wiring connections and mounting points should remain serviceable without destructive ceiling work.
Consider it when the screen must disappear into the ceiling and flatter retractable surface performance is important. Confirm projector, material, size and service requirements together.
Send MGF the room drawing, ceiling section, projector model, visible image size, aspect ratio, screen type, power and control requirements, quantity and destination market. Request the current model drawing before framing or cutting the ceiling.
Contact MGF Screens for an in-ceiling projection screen configuration.